The FLS1000-xS-t fluorescence lifetime spectrometer is a modular system for set measuring fluorescence decays in the time range (depending upon the detector tts) between -5 ps and 50 µs using the method of Time-Correlated Single Photon Counting (TCSPC) Faculty Incharge: Dr. Janardan Kundu, Dr. Jatish Kumar
Category: Chemistry
Powder XRD (Smart Lab 9 Kw -Rigaku)
Automated Multipurpose Powder X-Ray Diffractometer (Rotating anode X-ray source) can determine Powder Samples, Thin Films, Also having other techniques like SAXS, Battery attachment equipped with a high-accuracy theta-theta goniometer featuring a horizontal sample mount. Faculty Incharge: Dr. Vanchiappan Aravindan
C-Trap® Optical Tweezers – Fluorescence & Label-free Microscopy – Lumicks
C-Trap® Optical Tweezers is a dynamic single-molecule microscope to allow simultaneous manipulation and visualization of single-molecule interactions in real time. Faculty Incharge: Dr. Soumit Sankar Manda
Isothermal Titration Calorimetry (Malvern MicroCal ITC)
ITC measures heat released or absorbed during biochemical binding events to calculate binding affinity (K D ), stoichiometry (n), enthalpy (ΔH) and entropy (ΔS) in a single experiment. Faculty Incharge: Dr. Soumit Sankar Mandal
Bio Layer Interferometry – Octet® R4 Protein Analysis System
The 4-channel Octet® R4 instrument can be used for a wide range of analyses including kinetic analysis, titer of IgG and other proteins, reagent qualification, immunoassay development, bioprocess development, quality analysis, crude antibody screening, epitope binning/mapping, ligand binding assays, and small molecule analysis, elucidating cell signaling mechanisms, and infectious disease monitoring. Faculty Incharge: Dr. Soumit… Continue reading Bio Layer Interferometry – Octet® R4 Protein Analysis System
Cyclic Voltammetry – Biologic – SP 200 Potentiostat
For study various electrochemistry applications like Corrosion / Coating, Electrolysis Fundamental and analytical electrochemistry research, fuel cell and batteries, Sensors Faculty Incharge: Dr. Pankaj Kumar Koli
Benchtop NMR : Spinsolve 80 Ultra – Carbon – Magritek
This Benchtop NMR is capable of determining the molecular structure based on the chemical environment of the magnetic nuclei like 1H, 13C, 19F, T1, T2, HMBC, HSQC, DEPT, COSY etc. Faculty Incharge: Dr. Gopinath Purushothaman
Single Crystal XRD: Bruker D8- Venture Diffractometer Photon III – Duo
Single-crystal X-ray diffraction is most commonly used for precise determination of a unit cell, including cell dimensions and positions of atoms within the lattice. Bond-lengths and angles are directly related to the atomic positions. Both Mo and Cu sources are available for measurement. Faculty Incharge: Dr. Sudipta Roy
GCMS with HSS (Agilent)
For analysis of low molecular weight volatile and semi-volatile organic and inorganic compounds. EI and CI ionization sources with GC-FID (G3540A-Agilent 8890), GC-MSD (7078B) detectors and HSS 7697A (G4556A). Head Space provides an inert sample pathway for superior gas chromatography performance without analyte degradation or loss. Faculty In charge: Dr. Sudipta Roy
Defining the heats of reactions using the concept of ‘Extent of Reaction’
Ramabhadran, R. O. (2022). Defining the heats of reactions using the concept of ‘Extent of Reaction’. Resonance, 27(5), 753-767. DOI: 10.1007/s12045-022-1370-x